NameDescriptionContent

E-mail

Password

Register Forgot password?
English
Button Text
​​Your position
PDLC-LC Outdoor Cable Assembly
    Publish time 2022-04-13 14:42    

1. Multi-purpose Outdoor.

2. For connection between distribution box and RRH. 3.Deployment in Remote Radio Head cell tower applications.


Application

1. Multi-purpose Outdoor.

2. For connection between distribution box and RRH. 3.Deployment in Remote Radio Head cell tower applications.


Features

1.Standard DLC connector, well connected with standard LC adaptor 

2.Low insertion loss and added loss.

3.Height of attenuation.

4. Flexibility with small bending radius and excellent cable routing properties. 

5.End-face geometry and quality superior than IEC and Telcordia standards. 

6.The material in the jumpel cable are all-weather and UV-resistant.

7.IP67 water and dust protection

8. Mechanical performance: IEC 61754-20 standard. 9.RoHS and REACH materials compliant.


Connector Types

Type

Reference

Note

 

LC

 

IEC 61754-20

 

Single mode duplex

APC: Green connectors UPC: Blue connectors

Multimode duplex

UPC: Grey Connectors


Dimensional Diagrams

1. PDLC Outddoor cable Assemblies


Patch cord versions

Jumper tolerance requirement

Overall length (L) M

length of toleranceCM

0L≤20

+10/-0

20L≤40

+15/-0

L40

+0.5%L/-0


Cable Structure


Cable Parameters

 

Cable Count

 

Out sheath Diameter

MM)

 

Weight

KG)

Minimum allowable Tensile Strength (N)

minimum allowable Crush Load

N/100mm)

Minimum Bending Radius (MM)

 

Storage temperature

short term

long term

short term

long term

short term

long term

2

7.0±0.3

68

600

1000

2000

3000

20D

10D

-20~~+70


Cable Structure

Cable Parameters

 

Cable Count

 

Out sheath Diameter

MM)

 

Weight

KG)

Minimum allowable Tensile Strength

(N)

Minimum allowable Crush Load

N/100mm)

Minimum Bending Radius

(MM)

 

Storage temperature

short term

long term

short term

long term

short term

long term

2

7.0±0.3mm

50

600

1000

1000

2000

20D

10D

-20~~+70


Optical Characteristics

 

Item

Parameter

 

Reference

Single mode

Multimode

Insertion loss

Typical value≤0.15dB;Maximum≤0.30

Typical value≤0.15dB;Maximum≤0.30

IEC 61300-3-34

 

Return loss

 60dB (APC);

 50dB (UPC)

 

≥30dB (UPC)

 

IEC 61300-3-6


End-Face Geometry

Item

UPC (Ref: IEC 61755-3-1)

APC (Ref: IEC 61755-3-2)

Radius of curvature (mm)

7 to 25

5 to 12

Fiber height (nm)

-100 to 100

-100 to 100

Apex offset (μm)

0 to 50

0 to 50

APC angle (°)

/

 ±0.2°

Key error (°)

/

0.2° max


End-Face Qualty (SM)

Zone

Range (μm)

Scratches

Defects

Reference

A: Core

0 to 25

None

None

 

 

 

IEC 61300-3-35:2015

B: Cladding

25 to 115

None

None

C: Adhesive

115 to 135

None

None

D: Contact

135 to 250

None

None

E: Rest of ferrule

None

None


End-Face Qualty (MM)

Zone

Range (μm)

Scratches

Defects

Reference

A: Core

0 to 65

None

None

 

 

 

IEC 61300-3-35:2015

B: Cladding

65 to 115

None

None

C: Adhesive

115 to 135

None

None

D: Contact

135 to 250

None

None

E: Rest of ferrule

None

None


Mechanical Characteristics

Test

Conditions

Reference

Endurance

500 matings

IEC 61300-2-2

Vibration

Frequency: 10 to 55Hz, Amplitude: 0.75mm

IEC 61300-2-1

Cable retention

400N (main cable); 50N (ranch part)

IEC 61300-2-4

Strength of coupling mechanism

80N for 2 to 3mm cable

IEC 61300-2-6

Cable torsion

15N for 2 to 3mm cable

IEC 61300-2-5

Fall

10 drops, 1m drop height

IEC 61300-2-12

Static lateral load

1N for 1h (main cable); 0.2N for 5min (ranch part)

IEC 61300-2-42

Cold

-25°C, 96h duration

IEC 61300-2-17

Dry heat

+70°C, 96h duration

IEC 61300-2-18

Change of temperature

-25°C to +70°C, 12 cycles

IEC 61300-2-22

Humidity

+40°C at 93%, 96h duration

IEC 61300-2-19


400-000-0000
400-000-0000
Want Customize, Contact Us
  • Name
  • Phone*
  • Email*
  • Message
Submit