NameDescriptionContent

E-mail

Password

Register Forgot password?
English
Button Text
​​Your position
Mini IP Outdoor Cable Assembly SC
    Publish time 2022-04-15 14:21    

1. Multi-purpose Outdoor.

2. For connection between distribution box and RRH. 3.Deployment in Remote Radio Head cell tower applications.


Application

1. Multi-purpose Outdoor.

2. For connection between distribution box and RRH. 3.Deployment in Remote Radio Head cell tower applications.


Features

1.Cost effective solution for in house termination. 

2.Low insertion loss and added loss.

3.Height of attenuation.

4.IP67 water, dust proof and corrosion resistant

5. The material in the jumpel cable are all-weather and UV-resistant. 

6.Mechanical performance: IEC 61754-20

7.RoHS and REACH materials compliant.


Connector Types

 

Type

Reference

Note

 

 

SC

 

 

IEC 61754-4

Single mode Simplex

APC: Green connectors UPC: Blue connectors

Multimode Simplex

UPC: Grey Connectors


Dimensional Diagrams

1. Mini IP SC Outer Cable Assemblies

 


Patch cord versions

Jumper tolerance requirement

Overall length (L) M

length of toleranceCM

0L≤20

+10/-0

20L≤40

+15/-0

 

L40

+0.5%L/-0


Cable Structure

 

Cable Parameters

 

 

Cable Count

 

Out sheath Diameter

MM)

 

 

Weight

KG)

Minimum allowable Tensile Strength (N)

minimum allowable Crush Load

N/100mm)

Minimum Bending Radius (MM)

 

Storage temperature

short term

long term

short term

long term

short term

long term

1

5.0±0.2

26.5

800

400

2000

1000

20D

10D

-20 ~~ +60


Cable Structure

 

 Cable Parameters

 

 

 

Cable Count

 

 

 

Out sheath Diameter

MM)

 

 

Weight

KG)

Minimum allowable Tensile Strength (N)

minimum allowable Crush Load

N/100mm)

Minimum Bending Radius (MM)

 

Storage temperature

short term

long term

short term

long term

short term

long term

1

(4.0±0.2)x(7.0±0.2)

42

1350

400

2200

1000

20D

10D

-20 ~~ +60

 

Optical Characteristics

 

 

Item

Parameter

 

 

Reference

Single mode

Multimode

Standard

Elite

Standard

Elite

 

Insertion loss

Typical≤0.30dB Max≤0.75dB

Typical≤0.15dB Max≤0.35dB

Typical≤0.50dB Max≤0.25dB

Typical≤0.10dB Max≤0.35dB

 

IEC 61300-3-34

Return loss

 50dB (PC)

 60dB (APC)

 55dB (PC)

 65dB (APC)

≥30dB(PC)

≥30dB(PC)

IEC 61300-3-6

 

End-Face Geometry

Item

UPC (Ref: IEC 61755-3-1)

APC (Ref: IEC 61755-3-2)

Radius of curvature (mm)

10 to 25

5 to 12

Fiber height (nm)

-100 to 100

-100 to 100

Apex offset (μm)

0 to 50

0 to 50

APC angle (°)

/

 ±0.2°

Key error (°)

/

0.2° max


End-Face Qualty (SM)

Zone

Range (μm)

Scratches

Defects

Reference

A: Core

0 to 25

None

None

 

 

 

 

IEC 61300-3-35:2015

B: Cladding

25 to 115

None

None

C: Adhesive

115 to 135

None

None

D: Contact

135 to 250

None

None

E: Rest of ferrule

None

None


End-Face Qualty (MM)

Zone

Range (μm)

Scratches

Defects

Reference

A: Core

0 to 65

None

None

 

 

 

 

 

IEC 61300-3-35:2015

B: Cladding

65 to 115

None

None

C: Adhesive

115 to 135

None

None

D: Contact

135 to 250

None

None

E: Rest of ferrule

None

None

 

Mechanical Characteristics

Test

Conditions

Reference

Endurance

500 matings

IEC 61300-2-2

Vibration

Frequency: 10 to 55Hz, Amplitude: 0.75mm

IEC 61300-2-1

Cable retention

100N (main cable); 50N (connector part)

IEC 61300-2-4

Strength of coupling mechanism

80N for 2 to 3mm cable

IEC 61300-2-6

Cable torsion

15N for 2 to 3mm cable

IEC 61300-2-5

Fall

10 drops, 1m drop height

IEC 61300-2-12

Static lateral load

1N for 1h (main cable); 0.2N for 5min (ranch part)

IEC 61300-2-42

Cold

-25°C, 96h duration

IEC 61300-2-17

Dry heat

+70°C, 96h duration

IEC 61300-2-18

Change of temperature

-25°C to +70°C, 12 cycles

IEC 61300-2-22

Humidity

+40°C at 93%, 96h duration

IEC 61300-2-19

 

400-000-0000
400-000-0000
Want Customize, Contact Us
  • Name
  • Phone*
  • Email*
  • Message
Submit