Products

ProductField Mountable Fiber Optic Connector

TypeSC/PCSC/APC        

Adapted with Cable:2×3Φ0.9mmΦ2.0mmΦ3.0mm

Locking Method Included:Spiral Types and Shell Types


Field Mountable Fiber Optic Connector SC/PC


Field Mountable Fiber Optic Connector SC/APC


CodesSee chart 1

Table 1 Codes

Serial No.

Item

Code

1

Product Name

Field Mountable Fiber Optic ConnectorFMC

2

Assembly Method

MechanicalM

3

Fiber Type

Single ModeSM    Multi ModeMM

4

Structure

SC PlugSCP    SC PlugSCS

FC PlugFCP    FC PlugFCS

LC PlugLCP    LC PlugLCS

5

Shape of Plug Endface

PCAPC

6

Cable or Fiber

Fiber250μm):F250Fiber900μm):F900

CableDrop):CD   CableΦ3.0mm):C30

CableΦ2.0mm):C20CableElse):Diameter

7

Connecting Points

Single PointsSP     Multiple PointsMP

Inspection tem, Method, Standard and Sampling Plan(See Table 2)

Table 2  Inspecting Items, Method, Standard and Sampling Plan

Item

Method

Standard

Sampling Plan

Appearance

1.Visual Inspection

2.at 400× amplifier

1No obvious scratchchipsdeformation and meets the specification type

2See Table 3

Normal StandardAQL 0.04

Dimension

CCD

According to the Drawings

Normal StandardAQL 0.04

End face dimension

3D Interferometer

Type

Radiusmm

Apex  offset(μm)

Fiber

(nm)

PCФ2.5㎜)

1025

≤50

±50

PCФ1.25㎜)

725

≤50

±50

APCФ2.5㎜)

515

≤50

±100

APCФ1.25㎜)

512

≤50

±100

Normal StandardAQL 0.04

Insertion Loss

I/R Test

Ave≤0.2dBMax≤0.4dB

Normal StandardAQL 0.025

Return Loss

I/R Test

PC≥40dBAPC≥55dB

Normal StandardAQL 0.025

Average Assembly Time

skilled operator

≤3mins

Normal StandardAQL 0.025

One-time Assembly Yield

skilled operator

≥97%

At least 97 of 100 are qualified

Repeatability

skilled operator

≥5 times

Normal StandardAQL 0.025




Table 3  End face appearance  tested by 400 times magnifying glass

Test area

Standard

area

area coverage

scratch

spot

shine spot/

white spot

crack

1

Φ25μm within

not allowed

not allowed

not allowed

not allowed

2

Φ25μmΦ60μm

width≤1 μm qty≤2pcs.

Diam.≤1μm

qty≤2pcs.

not allowed

not allowed

3

Φ60μmΦ125μm

width≤2 μm qty≤3pcs.

Diam.≤2μm

qty≤3pcs.

not allowed

not allowed

4

Φ125μmglue gap

width≤1μmlength≤60μm

5

end face of ceramic (Φ125μmΦ400μm)

width≤3μm

qty≤3pcs.

Diam.≤5μm

qty≤3pcs.

Diam.≤3μm

qty≤3pcs.

not allowed

Table 4 Inspecting ItemsRequirements and Standards

Items

Requirements

Standards

IL

I/R Test

Ave.≤0.2dBMax≤0.4dB

RL

I/R Test

PC≥40dBAPC≥55dB

Ave. assembly time

skilled operator

≤3mins

Right First time

skilled operator

≥97%

Repeatability

Pull and Push 10 times

Il range≤0.2dbRl range ≤4db

No mechanical damage, as deformation cracking or relaxing and so on

High temp

+8596h

Il range≤0.2dbRl range ≤4db

No mechanical damage, as deformation cracking or relaxing and so on

Low temp

-4096h

Il range≤0.2dbRl range ≤4db

No mechanical damage, as deformation cracking or relaxing and so on

Temp. cycle

-40+8521CyclesTotal 168 h

Il range≤0.2dbRl range ≤4db

No mechanical damage, as deformation cracking or relaxing and so on

Damp and Hot

+7595%96 h

Il range≤0.2dbRl range ≤4db

No mechanical damage, as deformation cracking or relaxing and so on

Water Immersion

25±2168 hTap water

Il range≤0.2dbRl range ≤4db

No mechanical damage, as deformation cracking or relaxing and so on

Repeatability

5 times

Il range≤0.2dbRl range ≤4db

No mechanical damage, obvious scratch

Vibrate

(Sine)

Frequency10-50Hz

Scanning45times/min

Amplitude0.75mm Half

Time: three directions,2h each

Il range≤0.2dbRl range ≤4db

No mechanical damage, obvious scratch

Drop

Heightabout 3.2mTimes8

Il range≤0.2dbRl range ≤4db

No mechanical damage, as deformation cracking or relaxing and so on

Mechanical Durable

Pull and Push500 times

Il range≤0.2dbRl range ≤4db

No mechanical damage, as deformation cracking or relaxing and so on

Tension

FO250μm):4N

FO900μm):10N

Cable20Nonline

Cable30Noffline2mins

Il range≤0.2dbRl range ≤4db

No mechanical damage, as deformation cracking or relaxing and so on

TorsionCable

Load15N

Rate10 times/min

Times200

Il range≤0.2dbRl range ≤4db

No mechanical damage, as deformation cracking or relaxing and so on

Sample Inspection Procedures

Chart 5 Sample Inspection Procedures

Inspecting Sequence

Third Party Testing

Inner Testing

Samples

Periodic Inspection (Month)

Samples

Periodic Inspection (Month)

1IL

RL

Ave assembly time

One-time Assembly Yield

40

24

100

6

2Repeatability

Low Temp

6

24

12

6

3Temp cycle

VibrateSine

Drop

6

24

12

6

4-High Temp

-Mechanical Durable

6

24

12

6

5Damp and Hot

Tension

TorsionCable

6

24

12

6

6Water Immersion

4

24

12

6

7Repeatability

4

24

12

6