NameDescriptionContent

E-mail

Password

Register Forgot password?
English
T

技术专区

Button Text
​​Your position
Surfiber PLC Splitter end face requirement
Source: | Author:Surfiber-Sabrina | Published time: 2022-07-12 | 619 Views: | Share:

Surfiber PLC Splitter end face requirement

The connector end face grade can be divided into A zone, B zone and C zone according to the degree of importance, and the 400X end face detector is used for detection.


Area

Defect classification

Judgments based

Judgments

   Area A (within 25um)

No defects are allowed

No defects

Failed

Area B (25~120um)

scratch thickness

Width≤2um;≤3um 3pcs

Pass

Width>3um

Failed

scratch

have any black scratches

Failed

Little point

Defect diameter>3 um

Failed

width≤2um≤3um 3pcs

Pass

            Area C (120-130um)

white scratch

width≤2um;≤5um 3pcs

Pass

Little point

 width≤2um           ≤5um 3pcs

Pass

Area D(130~250um)

defect

Can be wiped off the dirt

Failed

Defect diameter≤10um

Pass

Defect diameter10um

Failed


Remark:

1. The core is not allowed to have missing pieces and cracks.

2. Black scratches are not allowed in all areas of the end face.

3. The end face must be completely polished, and no cross scratches are allowed.

4. The end face is magnified 400 times, and no wipeable dirt is allowed in the 0-250um area.

5. According to the degree of importance, the connector end face grade can be divided into A, B, C and D, as follows:


400-000-0000
400-000-0000